The following table gives some examples of simulators compliant with the 50 kV/m electric field required in MIL-STD-461 RS105.
| GENERATOR REFERENCE
| RADIATING LINE
REFERENCE
| EUT dimension in meter | SYSTEM OVERALL DIMENSIONS in meter | ||||
| WIDTH | LENGTH | HEIGHT | WIDTH | LENGTH | HEIGHT | ||
| EMP25K-2-23 | RL50-50 | 0.65 | 0.4 | 0.17 | 0.8 | 2.0 | 0.5 |
| EMP80K-2-23 | RL | 1.0 | 1.3 | 0.5 | 2.5 | 6.6 | 1.8 |
| EMP200K-2-23 | RL270-50 | 1.6 | 1.9 | 0.8 | 3.75 | 10.9 | 2.7 |
| EMP280K-2-23 | RL360-50 | 2.15 | 2.5 | 1.1 | 5.0 | 14.3 | 3.6 |
| EMP360K-2-23 | RL540-50 | 3.3 | 3.8 | 1.6 | 7.5 | 21.0 | 5.4 |
| EMP520K-2-23 | RL720-50 | 4.0 | 5.5 | 2.1 | 10.0 | 28.0 | 7.2 |
| EMP800K-2-23 | RL1080-50 | Dimensions available on request | |||||
| EMP1000K-2-23 | RL1290-50 | ||||||
| EMP1400K-2-23 | RL | ||||||
| EMP2000K-2-23 | RL2500-50 | ||||||
| RS105 simulators using GTEM and coaxial generators are available on request | |||||||
|
| EQUIPMENT | REFERENCE | SPECIFICATIONS |
| Movable simulators for small devices | Generator | EMP25K | Generator with 25 kV erected voltage |
| Transmission line | RL50 | Compact radiating lines to place on a table. Height of 0.5 m | |
| Movable indoor simulators | Generator + control unit | EMP80K, EMP170K, EMP280K, EMP360K or EMP520K | Generators with 80 kV, 170 kV, 280 kV, 360 kV or 520 kV erected voltage |
| Transmission line | RL180, RL270, RL360, RL540 or RL720 | Movable radiating lines. Heights of 1.8 m, 2.7 m, 3.6 m, 5.4 m or 7.2 m | |
| Fixed outdoor simulators | Generator + control unit | EMP360K to 2000K | Generators from 360 kV up to 2 MV erected voltage |
| Transmission line | RL540 to RL2500 | Fixed radiating line. Heights from 5.4 m to 25 m | |
| Pulse monitoring | Voltage monitor | SV1G | Monitoring of the generator output pulse |
| Free field sensor | SFE3-5G | Free space field sensors up to 3.5 GHz | |
| Ground field sensor | SGE3-5G | Ground plane field sensor up to 3.5 GHz | |
| Passive integrator | ITR1-2U | Passive integrator for ground plane field sensor and voltage monitor | |
| Balun | BL3-5G | Balun for free space field sensor | |
| Measurement equipment | Data transmission | MOL3000 & FCLB50 | Analog optical link with 50 m single mode fibre |
| Shielded box | SB3G | Enclosure to protect the oscilloscope from the EM pulse | |
| Oscilloscope | OD4C600M | 600 MHz bandwidth, 10 Gs/s, 4 channels | |
| Software |
| Computer control of the simulator and electromagnetic field measurement |
功能特点:
1)进口RS105测试系统设备采用全固态Marx发生器架构,配合油浸式脉冲成形网络,实现50 kV/m场强输出,上升时间≤1.8 ns,满足MIL-STD-461G最新修订要求。
2)内置双通道光纤遥测模块,在强电磁环境下实时传输场强波形数据,信噪比优于60 dB,确保测量精度。
3)辐射线结构采用渐变阻抗匹配设计,驻波比≤1.3,有效减少反射波导致的场强不均匀性,测试区域均匀度优于±3 dB。
4)系统集成自检与校准程序,可自动补偿脉冲幅值漂移,校准周期延长至12个月,降低运维频次。
5)防护等级IP54,支持-20℃至+50℃宽温运行,适用于室内外固定及移动部署场景。
适用行业场景:
1)军用航空电子:机载雷达、通信系统在雷电间接效应下的电磁脉冲适应性验证。
2)新能源汽车:电驱总成、BMS、电机控制器在高压瞬态场中的抗扰度评估。
3)工业自动化:PLC、变频器、伺服驱动器在强电磁脉冲环境下的误动作阈值测试。
4)医疗器械:心脏起搏器、神经刺激器等有源植入设备在脉冲场中的安全余量分析。
5)科研实验:校准亚纳秒级脉冲传感器响应线性度,验证场强探头溯源链。
与其他产品对比:
| 对比项目 | 进口RS105系统 | 国产同类系统 |
|----------|--------------|--------------|
| 上升时间 | ≤1.8 ns | ≥2.5 ns |
| 场强均匀度 | ±3 dB | ±5 dB |
| 光纤遥测带宽 | 3.5 GHz | 2 GHz |
| 自检校准周期 | 12个月 | 6个月 |
| 防护等级 | IP54 | IP30 |
| 溯源标准 | NIST可溯源 | 国内计量院 |
核心优势:
1)全链路计量溯源:场强探头经NIST可溯源校准,不确定度≤±1.5 dB,测试数据具备国际互认性。
2)脉冲重复频率可调范围0.1~10 Hz,适配MIL-STD、GJB、DO-160等多标准波形参数。
3)辐射线高度与长度按1:5比例设计,确保EUT放置区内场强波动小于±2 dB,重复性优于98%。
4)支持远程控制与数据加密传输,满足涉密场所信息安全要求。
选型与使用注意事项:
1)EUT最大高度不应超过辐射线高度的1/3,否则场强畸变率将超过允许值±5%。
2)地面接地网电阻需≤0.5 Ω,接地母线截面积≥50 mm2,否则脉冲前沿会拉伸至2.5 ns以上。
3)光纤链路超过30 m时须加装中继放大器补偿光损耗,避免信号衰减超3 dB。
4)去离子水循环系统每6个月更换一次滤芯,电导率需维持在≤1 μS/cm。
5)操作人员须穿戴防静电腕带,测试前关闭区域内所有无线发射设备,防止意外触发。
常见问题解答:
1)进口RS105测试系统设备能否直接用于GJB 151B测试?
可以。通过更换外置耦合电容网络模块(如100 pF/50 kV),即可覆盖国军标要求的10 kV/m~50 kV/m场强范围,波形参数无需调整。
2)设备年度维护费用大约多少?
主要耗材为去离子水滤芯和光纤端面清洁套件,年综合成本约1.2万元;高压开关及电容组件质保期内免维护,质保期外可提供定检服务。
3)现场安装是否需要特殊地基处理?
需浇筑C30混凝土基础,预埋8根M20地脚螺栓,深度不小于800 mm,基础承重不小于5吨,否则可能引起设备倾覆或脉冲波形抖动。
4)测试中EUT意外受试后如何快速排查损坏?
建议使用内置的脉冲计数器记录施加次数,结合光纤遥测波形峰值对比,若波形出现截尾或幅值下降>10%,需立即停机检查EUT输入端保护电路。
| 品牌 | Montena |
| 价格: | ¥211800元 |
| 型号 | RS105 |
| 原产地 | 国产 |
| 产品数量 | 不限 |
| 产品关键字: | RS105测试系统 |
| 所属行业 | 电磁兼容 |
| 发布时间 | 2024/1/15 16:55:40 |