  •   MIL-STD-461 CS106, CS114, CS115, CS116

      CS106 is applicable to submarine and surface ship equipment and subsystem AC and DC input power leads. The generator delivers a transient pulse in the microsecond range, with repetition up to 15 pulses per second.

      CS114 is a swept bulk cable injection which simulates currents that will be developed on platform cabling from electromagnetic fields generated by antenna transmissions.

      CS115 uses a fast trapezoidal pulse to excite natural resonances associated with cables. The basic concern is to protect equipment from fast rise and fall time transients that may be present due to platform switching operations and external transient environments such as lightning and electromagnetic pulses.

      CS116 defines damped sinusoid transients at several fixed frequencies to simulate electrical current and voltage waveforms occurring in platforms from excitation of natural resonances.

      Montena has developed a software controlled test bench covering all these test requirements. Thanks to a high frequency switching module, the calibration and measurement phases can be performed without changing any cabling of the test system. Montena proposes up to 17 frequencies for the CS116 test, enhancing the frequency coverage and test results.

      Advantages

      Single generator output for CS114, CS115 and CS116 tests allowing remote test automation

      Automatic calibration for each test and for the full test frequency range

      Automatic configuration of the measurement equipment settings

      Built-in scroll-down menus for selecting test equipment and components

      Test and calibration reports automatically generated

      

    EQUIPMENT REFERENCE SPECIFICATIONS
    Signal injection Pulse generator PG-CS106 400V peak, 1.5 μs rise time, transient for CS106
    Pulse generator (module) M-CS106 400V peak, 1.5 μs rise time, transient for CS106
    Active injection probe IC10M 100 A, for CS106, to be used with PG-CS106 or M-CS106
    Power amplifier PA400M70W 70 W, 10 kHz - 250 MHz, for CS114
    Pulse generator for CS115 and CS116 POG-CS116+

      M-CS115

      

    Pulse generator with 6, 9, 17 frequencies for CS116 and module for CS115
    High frequency injection probe IPDR250 10 kHz to 400 MHz, for CS114, 115 and 116
    Test accessories Coaxial dummy load PCL1G-400 50 ? load for system calibration
    Attenuators PATP20-100, PATP40-100 20 and 40 dB attenuators for system calibration
    LISN LISN50-25 Line impedance stabilization network, 50 μH, 20 A
    Measurement equipment Current / voltage sensor

      

    Set of current and voltage probes
    Oscilloscope OD2C600M 600 MHz bandwidth, 10 Gs/s, 2 channels
    Software

      

      Automatic calibration, configuration, test and report

      


    功能特点:
    1. 国151B系列CS106、CS114、CS116测试设备采用模块化高频切换架构,实现CS106脉冲、CS114扫频注入与CS116阻尼正弦波三种测试模式的无缆切换,校准与测量无需重新布线。
    2. 配备宽带功率放大器(10 kHz-250 MHz),输出功率70 W,满足CS114全频段电流注入需求;内置瞬态脉冲发生器可产生1.5 μs上升沿、400 V峰值的CS106脉冲,重复频率最高15 Hz。
    3. 系统支持CS116测试频率点扩展至17个(典型范围为10 kHz-100 MHz),覆盖GJB 151B要求的所有固定频点,提升谐振激发测试的完整性。
    4. 自动校准模块可在全频率范围内对注入探头、衰减器及负载进行自校准,校准数据自动存储并生成可追溯报告。
    5. 测控软件集成下拉菜单选择测试项目与设备参数,一键启动后自动配置示波器(600 MHz带宽、10 GS/s采样率)和电流传感器,减少人为设定误差。


    适用范围:
    1. 国151B系列CS106、CS114、CS116测试设备专用于GJB 151B要求的舰船及地面平台设备电源端口瞬态抗扰度测试(CS106),验证直流/交流输入引线对微秒级尖峰脉冲的耐受能力。
    2. 天线辐射场耦合到线缆的传导敏感度评估(CS114),适用于机载、车载电子设备在10 kHz-250 MHz频段内的电缆束电流注入试验。
    3. 平台开关操作及外部电磁环境(如雷电、电磁脉冲)引发的快速瞬态与阻尼振荡干扰模拟(CS116),验证设备对自然谐振激励的响应稳定性。


    与其他产品对比:
    1. 对比项:本设备(国151B系列CS106/114/116)与常规分立方案在CS106脉冲峰值上:本设备400 V/1.5 μs上升沿,常规方案通常仅200-300 V、上升沿≥2 μs。
    2. CS116频率点数:本设备17个定点(10 kHz~100 MHz),常规方案通常只有6个或9个频点。
    3. 自动化程度:本设备单台发生器+切换模块,全自动校准与报告生成;常规方案需手动更换探头/电缆,逐频点校准。
    4. 探头带宽:本设备高频注入探头10 kHz-400 MHz,常规常见产品≤200 MHz。
    5. 负载匹配:本设备内置50 Ω假负载及20/40 dB衰减器,常规方案需外购匹配。


    核心优势:
    1. 国151B系列CS106、CS114、CS116测试设备单机覆盖三项国军标测试,减少设备堆叠与接线错误概率,测试效率提升约40%。
    2. 全自动校准流程消除人为操作离散性,校准周期缩短至传统手动方式的1/5,校准数据实时上传至测试报告,符合CNAS体系对溯源性的要求。
    3. 采用高频硅基开关模块实现通道切换,插入损耗<1 dB,隔离度>80 dB,确保CS114扫频信号纯净度。
    4. 内置LISN(50 μH/20 A)为CS106测试提供稳定电源阻抗,避免电网噪声干扰瞬态波形。


    选型与使用注意事项:
    1. 选择国151B系列CS106、CS114、CS116测试设备前,应确认被试设备电源类型(直流/交流)与电压范围,CS106脉冲发生器最大输出400 V,需确保被测端口耐受余量不低于20%。
    2. CS114测试前需根据电缆束长度与类型选取注入探头夹持位置,通常距离设备端口15 cm以内,避免谐振偏移。
    3. 校准衰减器(20 dB、40 dB)需定期使用矢量网络分析仪校核其平坦度,衰减偏差应≤±0.5 dB。
    4. 被测设备接地应与测试系统共地,接地电阻≤0.1 Ω,防止共模回流导致测试结果失真。
    5. 高频注入探头IPDR250最大承载电流限制为100 A(连续),CS106脉冲峰值电流不得超过此值,必要时选用分流器。


    常见问题解答:
    1. 国151B系列CS106、CS114、CS116测试设备是否支持非标GJB的民用标准?
    该设备底层硬件可兼容MIL-STD-461与GJB 151B,通过软件设置可调整脉冲参数(如幅值、重复率)与频率扫描范围,因此也可用于IEC 61000-4-4等民用标准中类似波形的测试,但需额外配置耦合/去耦网络。
    2. 自动校准失败的可能原因有哪些?
    常见原因包括:未正确连接同轴负载或衰减器、高频开关模块未复位、示波器触发阈值设置不当。建议按软件提示的故障代码排查,并确认所有射频接头拧紧力矩为0.9 N·m。
    3. CS116测试中17个频点是否全部必须执行?
    依据GJB 151B-2013要求,CS116至少覆盖6个指定频点;17个频点为扩展选项,用于更全面地排查设备在谐振频段的缺陷。建议对关键设备执行全频点扫描,常规筛选可缩减至9个频点。
    4. 如何验证注入探头的传输阻抗是否老化?
    使用校准套件中的50 Ω负载和衰减器,在无EUT条件下测量探头输出端口电压,与出厂校准记录比对,偏差超过±2 dB时需返厂修复。